Leveraging on our industrial expertise, we offer a huge collection of hot and cold insulation products. These products are used in various segments for different insulation applications. Its prominent features include good thermal resistance, excellent chemical resistance, fine heat resistance and dimensional stability. All the hot and cold insulation products can be customized according to clients’ specifications.
|
 |
 
 
| Twiga Flexible DuctWe are engaged in manufacturing Twiga Flexible Duct, that is used in various industries for different insulation applications. Fabricated using high quality raw material. Compliant with the international industrial norms, these are also available in customized specifications to the clients. These are widely appreciated for their:-
- High thermal resistance
- Excellent chemical resistance
- Fine heat resistance
- Dimensional Stability.
|
 
 | Rubber Pipe Section SelvesNo flame spread when fire tested k-flex st does not generate flaming droplets, has no flame spread and has a low fire propagation index. These combined, meet the fire performance requirement of class "o" as defined in building regulations by bs standards. Offers increased safety and protection. high water vapour diffusion resistance k-flex st closed cell elastomeric insulation has a high diffusion resistance factor . I that minimizes water vapour penetration, giving excellent long term performance! very low thermal conductivity k-flex st thermal conductivity is. At 0°c = 0,036 w/(m. K) giving energy savings. advantages of k-flex nitrile rubber insulation features • closed cell insulation material • higher density • lower thermal conductivity • high water vapour diffusion resistance (m) • fire rating class "o" • flexible • wide range of operating temperature • in-built vapour barrier benefits • uniform bonding & constant insulation value • higher stability • higher resistance to heat transfer • long term insulation efficiency with lower thickness • self extinguishing Non-dripping • ease of installation & reduced cost • one product for various applications • increased resistance to water ingress. |
 
 | Rock Wool Mattress  Rock Wool Mattress are made from lightly resin Bonded rock fibers with wire mesh machine stitched and Machine lay on one side used in boiler, equipment vessel tank, chimney, ESP, pipe & fitting. Duct & other industrial applications: - Operating Temp: Up to 700 C
- Sizes : Mattresses in the size of 1.22 mX1.52 m with wire mesh machine
- Density : 100, 120, & 150 Kg/m3
- Thickness: 25, 40, 50, 65, 75 & 100 mm
|
 
 | Polyurethane FoamOur range of finest quality Polyurethane Foam products are immensely used as a vehicle seat squab and bedding because of outstanding cushioning & heat retaining properties. These products are used in different industries and can be customized as per clients’ specific requirements. Polyurethane foam is available in slabs & pipe section, low thermal conductivity, low smoke emission and low water vapour permeability qualities are ideal for building & industrial insulation. - Operating Temp : - 200 C to 150 C
- Sizes : Slabs 1m X 0.5 m/ Pipe section to suite lines having 25 mm to 350 mm Dia meter.
- Thickness : 25, 40, 50, 65, 75 & 100 mm
|
 
 | Ceramic WoolWe offer different types of ceramic wool products that are used in diversified insulation applications. Some of the features of these products, which make it popular among our clients, include ideal blanket density, suitable thickness and long life. |
 
 | Rock Wool Slabs  Applications: - Rock wool Slabs are designed for a wide range of applications, at both high and low service temperatures. It can be used on flat or slightly curved surfaces for thermal and acoustic insulation. They are also suitable for thermal insulation of ducts, large vessels, cavity wall, curtain wall and sandwich panels.
Service Temperature: - Slabs when tested in accordance with DIN 52271 can withstand temperatures up to 750° C.
Fire-Safety: - Slabs are non combustible when tested in accordance with BS - 476 Part 4 and ASTM E -136.
Facing: - Slabs are available with Black glass tissue, Reinforced aluminium foil, Kraft paper and Glass cloth facings.
Thermal Conductivity: - Slabs show remarkably low thermal conductivity values,when tested in accordance with BS 874 : 1986.
Moisture: - Non-hygroscopic and non-capillary, it does not absorb any moisture from the air nor does moisture have any effect on the stability of the slabs.Water repellent slabs available on request.
Density: - Available from 48kg/m³ - 200 kg/m³ densities, and size of 1.0 meters x 0.6 meters. Non-standard sizes available on request.
Packing: - Slabs are packed in HDPE bags.
|
 
 | Mattresses | Application: |
| | wired mattresses conform to ASTM C - 553, C - 592 and BS- 3958 part 3. It is used in the thermal insulation of large vessels, boilers, small machinery, equipment, ducts, flanges, valves and plants operating at high temperatures. | | | | Service Temperature: | | Has a service temperature of 750° C when tested in accordance with DIN -52271, and ASTMC - 411. | | | | Fire-Safety: | | Non-combustible when tested in accordance with BS - 476 part - 4 and ASTM E - 136. Class1 when tested in accordance with BS - 476 part 7, (ASTM E- 84). | | | | Facing: | | wired mattresses are available with wired mesh on one or both sides in SS or GI. | | | | Moisture: | | Non-hygroscopic, non-capillary and does not absorb any moisture from the air. Moisture has no effect on the stability of the mattresses. | | | | | Density: | | | Available in densities from 70kg/m³ to 150kg/m³ in standard width of 1.22meters and length of 1.64meters. Non - standard sizes available on request. | | | | | Packing: | | | mattresses are packed in HDPE bags. . | |
| |
 
 | Pipe Section | Application: |
| preformed pipe section conforms to ASTMC - 547 and BS - 3958 - 4 and is used for thermal insulation of pipes in industrial plants and commercial buildings.
| | Service Temperature: | | pipe sections , when tested in accordance with DIN 52271 can withstand temperatures up to 750° C. | | Fire-Safety: Non-combustible when tested in accordance with BS-476 part 4 and ASTM E - 136. Class 1, when tested in accordance with BS- 476 part-7 and ASTM E - 84. | |
 
 | Glass WoolBacked by a pool of talent, we provide durable glass wool products that are popular for its properties of energy conservation and sound insulation. The main application areas of these products include construction and air conditioning industries. It is made from bonded glass fibers and is used for thermal and acoustic insulation. It is available with or without alluminium foil and is ideal for under deck insulation, over the false ceiling and for ducting. - Size : Rolls in standard width of 1.2mm
- Density : 16 , 24 , 32 , and 48 Kg/m3
- Thickness : 12, 25 , 40 , 50 mm.
|
 
 | Resin Bonded Rock WoolLeveraging on our industrial expertise, we offer a huge collection of hot and cold insulation products. These products are used in various segments for different insulation applications. Its prominent features includes: - Good thermal resistance
- Excellent chemical resistance
- Fine heat resistance
- Dimensional stability
All the hot and cold insulation products can be customized according to clients’ specifications. They are made from bonded rock fibers and are used for thermal and acoustic insulation of flat or curved surface. They are also available with facing of aluminum foil , glass cloth etc. for specification in under deck insulation,acoustic insulation, duck insulation, insulation over false ceiling transport appliances, partitions and industrial insulation. - Operating Temp : Up to 700 C
- Sizes : Slabs in the size of 1mtr X 0.6mtr with and without aluminum foil
- Density : 48 , 64 , 96 , & 144Kg/m3 Thickness : 25 , 40 , 50,65 , 75 & 100 mm
|
 
 | Loose wool | Application: |
| | Loose wool is unbonded wool Used for packing of flanges, valve boxes,automobile mufflers,ovens and many other items of industrial equipments. | | | | Service Temperature: | | Loose wool has a maximum service temperature of 750° C when tested in accordance with DIN 52271. | | | | Fire-Safety: | | Non-combustible when tested in accordance with BS 476 : Part 4 :1970 | | | | Thermal conductivity: | | Loose wool shows remarkably low thermal conductivity values. | | Moisture: | | | Non-hygroscopic, non-capillary and does not absorb any moisture from the air. Moisture has no effect on the stability of Loose wool. | | | | | Packing: | | | Loose wool is packed in 40kg HDPE bags. Other packing available on request. | | | | |
 
 | Friction Fibres | Application: |
| | | | Friction Fibres are used in non-asbestos organic formulations for friction products, such as railway brakes, commercial vehicle and passenger car linings and disc pads , clutch facings etc., Both wet and dry mixes can be used. It has excellent performance characteristics, and offers distinctive advantages over traditional filler / reinforcing materials. | | | | Advantages: | | | | High Temperature Stability: Rockinsul Friction Fibres have low conductivity and high heat resistance,preventing rapid overheating and improving brake life. Moisture Resistance: Rockinsul Friction Fibres are non-capillary and non-hygroscopic,giving good moisture resistance. Low Shot Content: Rockinsul Friction Fibres have shot content generally less than 3%. Hardness and Noise: Less abrasive than glass,ceramic and steel fibres. | | | | | Packing: | | | | | | Friction Fibres are packed in HDPE bags. Other packing available on request. | |
 
 | Chemically Cross Linked Polyethylene (SIL-XL-C) | Technical Data | | | | Product Name | Chemically Cross Linked Polyethylene (SIL-XL-C) | | Material Description | Fire Retardant Closed Cell Chemically Cross-Linked Polyethylene | | Material Form | Rolls Sheets and Tubings | | Application | Thermal & Acoustic Insulation | | Areas Of Application | A/C & Humidifications Ducts, Spandrel Insulation, Underdeck, Hot & Cold Water Pipelines,acoustic Flooring | | Operating Temperature | -40°C To + 115°C | | Colour | Grey | | Nominal Density (Kg/m3) | 30Kg/m3 | | Thermal Conductivity | Mean temperature (° C) | W/m°K | K Cal/hr m° C | | | 0 | 0.0315 | 0.0271 | | | 23 | 0.0325 | 0.0279 | | | 46 | 0.0383 | 0.0329 | | | Water Absorption % By Weight After 28 Days (As per ASTM D3575) | 4.35 | | Water Vapour Transmission Rate for Bare Foam in gm/m2 mm of Hg.hr(As per ASTM E 96) | 0.37 | | Tensile Strength (N/m2) | 27 | | Tear Strength (N/m) | 23 | | Compression (N/m2) | 2.9 | | Thermal Stability at 50°C For 48 Hours | No Visible Changes Observed | | U.V Weather resistance at 60°C For 100 Hours Exposure to Weatherometer | No Visible Changes Observed | | Oxygen Index , % (As per ASTM D 2863) | 29 | | Fire Characteristics | Conforms to BS 476 Part 7 Class "1" For surface spread of flame and also UL 94 HBF grade | | Ozone Resistance For 48 Hrs at 50° at 50 pphm | No Visible Changes Observed | | Fungus Resistance (As per ASTM G 21) | No Visible Growth Observed Rating -0 | Sound Transmission Class (9 mm SIL - XL - C Laminated With 12 mm Gypsum Board )
| 40DB | | Disclaimer -" The information contained in this technical data sheet is given in good faith The values given here are typical average values and are believed to be correct to the best of our knowledge, however this is user's responsibility to determine suitability of application. Supreme Industries Ltd makes no gurantee of results and assumes no obligation or liability in connection with this advice. | | | THE ABOVE MENTIONED SPECIFICATIONS ARE FOR REFERENCE PURPOSES ONLY | | | | | |
|